Standard electrical interface that complies with VITA standard modules;

Universal, open, user-configurable connectors;

Modular combination structure that can realize integrated transmission of multiple signals such as RF, optical, differential, single-ended, power, etc.;

High-speed differential modules are solder-free press-fit structures;

Transmission rate can reach 6.25 Gbps and can be expanded to 10 Gbps;

Single module differential pair number 32 pairs, node density The frequency reaches 113/inch (56 p a i r s/inch);

The RF module complies with the VITA 67 standard, and the working frequency is 18 GHz/40 GHz;

The optical fiber module complies with the VIAT 66 standard and adopts high-density MT-type optical fiber contacts.

Product Parameters

High-speed differential transmission performance
Differential characteristic impedance: 100Ω
Transmission rate: 6.25 Gbps
Crosstalk: Better than - 30dB
Low-level contact resistance: ≤40mΩ
Rated current: Single signal 1A
Insulation resistance: ≥1000MΩ
Withstanding voltage: 500V
Environmental performance
Operating temperature: - 55 ℃ ~ 125 ℃
Salt spray: 96h
Damp heat: According to GJB1217A, alternating damp heat 10d
Mechanical performance
Vibration: Sine 10 ~ 2000Hz, 196m/s2
Random 10 ~ 2000Hz, 0.2g2/Hz
Impact: 80g, half sine wave, 11ms duration
Mechanical life: 500 times
RF performance
Operating frequency: 0 ~ 40GHz
Characteristic impedance: 50Ω
RF insertion loss: ≤ 0.06√f (f: GHz)
VSWR: ≤ 1.15 + 0.01f (f: GHz)
Phase stability: DC ~ 18GHz: ≤ ±3°
DC ~ 40GHz: ≤ ±6°
Isolation: Better than -90dB (500MHz ~ 18GHz)
Better than -70dB (1GHz ~ 40GHz)
RF leakage: Better than -80dB (2 ~ 3GHz)
Optical transmission performance
Insertion loss: ≤1.5dB
Bit error rate: no bit error greater than 10-12
Power transmission performance
Contact rated current: single row 2 channels, 8A each
Withstanding voltage: 500V
Insulation resistance: ≥1000MΩ

Product Application

FAQ

  • 1. How long does the lead time of products?

    35-45 working days.

  • 2. Can you accept that the product only has blue line without logo?

    Yes.

  • 3. Do you provide sample for test?

    Samples available.

  • 4. Has the product passed the tripartite systematic testing test?

    Yes, we can provide third-party testing reports. Third-party testing agencies systematically test the mechanical, environmental, electrical and other aspects of the product.

Send Message

Home Tel Mail Inquiry